Vectra - Recessed

Vectra combines distinctive styling with Ledalite’s revolutionary MesoOptics technology to bring the best of nature’s luminous aesthetics to indoor environments. Pure, comfortable brightness is evenly distributed throughout the space with exceptional glare control and energy efficiency.

Overview

Controlled brightness

MesoOptics technology enables superior visual comfort by delivering uniform brightness with exceptional glare control.


Earth-friendly

Sustainable building designers and building owners benefit with dramatic energy savings—up to 20% increased efficiency and 35% energy cost-savings over conventional recessed lighting systems.


Take your pick

Extensive lamping options and a range of housing sizes and configurations meet the needs of almost any recessed lighting application. The petite 1'x1' micro version is an ideal companion for corridors, meeting rooms, lobbies and other feature areas.


No tools required

Ledalite’s recessed lighting systems provide lamp and ballast access from below the ceiling without tools for quick and easy relamping and maintenance.

Performance

 

To determine approximate light levels using a simple lumen method calculator, please select CalcZone next to the ies file on the Philips Lighting eCatalog:
 
 

Exceptional Control and Efficiency

MesoOptics technology allows Vectra to have the best possible combination of lighting control and brightness with efficiencies that are almost 20% higher than other recessed lighting products.


Reduced Energy Consumption

When attempting to achieve a light level of 50 footcandles, most 2’x2’ recessed lighting systems will require two 40W TT5 lamps. Vectra requires only a single 55W TT5 lamp to meet this lighting level—a 35% reduction in lighting related energy costs.


Recessed Applications Guide

Vectra comes with a range of lamping options to suit a wide variety of lighting and energy efficiency needs. The chart to the right illustrates some of the options and their typical results.


Maintenance Made Easy

LED Luminaires

Push in the end corners of the fixture where the hinges are located.

 

To access the driver compartment, remove the screws on the upper reflector.

Gently lower the upper reflector and remove the LED driver.

 

Fluorescent Luminaires

Push up on the center channel and then slide the lens frame
to the side.

 

Gently lower the door. The hinge system allows you to access the inside without having to step off
the ladder.

The door swing out and away providing easy access to the lamp and ballast.

 

 

Options

Light Sources

Available with a wide range of light source options to suit many needs. The following table shows the options available for each housing size.

Size LED T8 T5 T5HO TT5
1'x4' 3600lm*,4400lm* 1,2 1,2 1,2  
2'x2' 3600lm*,4400lm* 2,3 2,3 2,3 1,2
2'x4' NA 2,3 2,3 1,2,3  
20"x2' NA 2,3 2,3 2,3 1,2
20"x4' NA 2,3 2,3 2,3

*Nominal values stated

LED options noted above are available in three LED color temperatures: 4000K, 3500K, and 3000K. See product specification sheets for more information.


Sizes

Designers can choose from a selection of housing sizes that provide different aesthetic and performance attributes.


Ceiling Integration

All Vectra products integrate with most standard T-grid ceilings of various T-bar heights and also offer mounting options for non-accessible ceilings.

Note: more details on ceiling integration are provided on the Technical navigation tab.

Slot T-Grids

The 2'x2' and 2'x4' sizes have an additional option to integrate with Slot T-Grid and some tegular tile ceiling types. These versions are designed to sit flush with Slot T-Grid ceilings.

Drywall kits

Optional drywall kits are available in all sizes for mounting in non-accessible ceilings.


Air Return

Air return versions are available in the 2'x2' and 2'x4' sizes.


10-Day QuickShip Delivery

 Quickship Some of the most popular versions of standard Vectra products are offered on Ledalite's QuickShip delivery program.

Upgrades + Accessories

Response Response Daylight Sensors provide a simple and affordable way to incorporate daylight controls into your lighting designs. Just add daylight, start saving and enjoy. Learn more.
Job Pack Job packs can help contractors reduce waste on the job site and save time with installation. Fixtures are protected with cardboard ends and then palletized and shrink-wrapped in bulk.

 

Technical

Dimensions

1'x4' (Fluorescent)

Vectra 1x4 Front Vectra 1x4 Side


1'x4' (LED)

Vectra 1x4 Front Vectra 1x4 Side


2'x2' (Fluorescent)

Vectra 2x2 Front Vectra 2x2 Side


2'x2' (LED)

Vectra 2x2 Front Vectra 2x2 Side


2'x4'

Vectra 2x4 Front Vectra 2x4 Side


20"x2'

Vectra 20Vectra 1 11/16 T-Bar


 

Mounting

Ceiling Integration

Vectra integrates with most common T-bar ceiling types.The 2'x2' and 2'x4' sizes have an additional option to integrate with Slot T-Grid and some tegular tile ceiling types.

D1 T-Grid 9/16 D1 Standard T-Grid 15/16 D1 Standard Slot T-Grid 9/16

Notes: Option D1 can be used with Slot T-Grid ceilings but it will not sit flush with the bottom of the T-Bar. Option D2 is not available in the 1'x4' size. For the 2'x2' and 2'x4' sizes, D2 is designed to sit flush with Slot T-Grid ceilings and some tegular tile ceiling types. Consult factory for more information on ceiling integration.

T-bar Heights

Integrated mounting tabs can be field-adjusted to various T-bar ceiling heights for fastening directly to the T-bar grid and/or tied off to the building structure.

Vectra 1 T-Bar Vectra 1 1/2 T-Bar Vectra 1 11/16 T-Bar

Note: the 1'x4' size is not compatible with 1-11/16" T-bar heights.


Drywall kits

Optional drywall kits are available in all sizes for mounting fixtures in standalone or continuous row configurations. Order separately, one kit per fixture.

Vectra Drywall Kit


Air Return

Air return versions are available in the 2'x2' and 2'x4' sizes. Side rails are finished in black.

Vectra Air Return


Wiring Options

Philips Ledalite offers numerous standard options for wiring, battery packs and switching.
Download Fluorescent Wiring Options PDF
Download LED Wiring Options PDF

The Vectra housing has multiple wire entrances (top or side) to facilitate different installation requirements. Continuous row housing includes knock outs for easy mounting end-to-end.

Some sizes/lamping combinations are available with master/satellite wiring to reduce the total number of ballasts required.


Vectra Spec Sheets