Pure | FX Technical

Dimensions

Mounting

Micro Hanger Kit

Optional Micro Hanger Kit enables installation in most common T-bar ceiling types and non-accessible ceilings.


Order separately, one kit per fixture.

Note: If required, redirection bars enable mounting 90° from fixture’s default orientation


Alternate Mounting Method

Fixtures can also be installed using conduit or channel (supplied by others).

Wiring

Ledalite offers numerous standard options for wiring, battery packs and switching.Download Wiring Options PDF

Specifications

Housing Construction

Die-formed, post-painted, 22 gauge cold-rolled steel (New York City version is 20 gauge).

Optical System

Optical assembly consists of flat non-glaze acrylic panels and extruded curved acrylic lens. A protected MesoOptics® film layer creates optimal light distribution and high efficiency. The optical frame is constructed from die-formed, spot-welded, 22 gauge cold-rolled steel assembled together with extruded aluminum profiles in a sturdy frame. The frame allows tool-free access to the inside of the fixture by way of expansion springs. Maintenance can be performed from below the ceiling.

Finish

Housing and frame are post-painted, high-quality powder coat with high-gloss and reflectance. Available in white only.

Ballast

Ballasts are electronic and available in 120V, 277V or 347V.

Mounting

Fixture is compatible with most common T-bar ceiling types and non-accessible ceilings. Butterfly mount brackets (attached to housing) are designed to work with optional hanger kit, or with EMT conduit or metal channel (supplied by others). Brackets allow post-installation adjustment of fixture height. Optional hanger kit includes hanger bars, T-bar anchor clips and redirection bars to enable mounting 90° from the fixture’s default orientation.

Wiring

Multiple wire entrances are available (top or side) to allow easy wiring access. Available with battery pack. Consult factory for details.

Weight

Maximum 7.1 lbs

Approvals

Certified to UL and CSA standards. City of Chicago Approved CCEA (Housing Option C). Designed to comply with NYC code requirements (Housing Option N).

IMPORTANT: Fixtures are rated for non-IC installations only. Do not install insulation within 3" (76mm) of any part of the luminaire.