Philips

Minuet Technical

Dimensions

Minuet Wall Technical Cross Section

Modules + Runs

Available in 4, 8 and 12ft modules. Module lengths do not include endcaps.

Different modules can be joined together to create continuous runs of various lengths. The following table shows how to configure typical runs using different modules.

Module Mount Spacing
4ft 4'2"
8ft 8'2"
12ft 12'2"
Run Length 4ft
Module
8ft
Module
12ft
Module
4' 1x    
8'   1x  
12'     1x
16'   2x  
20'   1x 1x
24'     2x
28'   2x 1x
32'   1x 2x

Endcaps

Minuet Technical End Cap Cross Section

Mounting

Flush wall mount system can be positioned anywhere along the fixture length. Mounts are adjustable to accommodate variances in wall straightness.  See Mounting Options


QuickLock Joining

Ledalite's QuickLock joining system provides simple installation and results in seamless hairline joints.


Integrated Leveling

Contractors can level fixtures quickly and easily with the integrated slide adjustor located at all ends and joints.

Electrical Connections

Luminaires are factory pre-wired with quick-wire plugs for easy installation. See Power Feeds + Electrical Connections

Wiring Options

Ledalite offers numerous standard options  for wiring, battery packs and switching. Download Wiring Options PDF

Specifications

Housing

6063 T5 extruded aluminum.

Weight

3.25 lb/ft

Optical System

Indirect: Constructed of highly specular aluminum and a highly reflective 24 gauage metal to produce an Indirect Asymmetric distribution.

Semi-Indirect: Constructed of highly-specular aluminum, white pre-painted metal and a concave perforated optical filter to produce a Semi-Indirect Asymmetric distribution

Direct/Indirect: Constructed of highly-specular aluminum to produce a Direct/Indirect Asymmetric distribution. Aluminum parabolic louver shall have 29 cells per 4ft. Louvers are 1-1/8” deep and 1-1/2” on center. Variable Optics kits provide the ability to add additional downlight where needed.

Endcaps

Molded high-impact polymer or mitered aluminum extrusion endcaps or end-coves.

Joints & Intersections

All joints shall be accomplished using Ledalite’s QuickLock joining system. Optional intersections in L, T or X configurations shall be mitered aluminum extrusion.

Mounting

Brackets attach to existing structure anywhere behind fixture. Fully adjustable mounting brackets to provide up to 1/8” wall variance and allow for vertical fixture leveling.

Electrical

All luminaires shall be factory pre-wired to section ends with quick-connect plugs.

Ballast

Electronic.

Approvals

Certified to UL & CSA standards.

Finish

High-quality powder coat, factory applied to meet AAMA 2603-98. Available in Ledalite Standard White (textured matte finish), a selection of optional factory colors (see factory color chart), or customer-specified colors. Consult factory for details.

Due to continuing product improvements, Ledalite reserves the right to change specifications without notice.