Power Feeds + Connections 120V, 277V

or 347V

  • All luminaires are pre-wired to ends with quick-wire connectors or quick-connect plugs.
  • Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
  • All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
  • All power cord jackets are factory pre-stripped.

Power Cords  Cord Styles  Electrical Connections

 

Power Cords

 

5 Conductor

  • Max. 10 amps in 1 circuit application
  • Max. 5 amps per circuit in a 2 circuit application
  • Max. 600V
  • Good for 1 circuit feeds with 0-10v dimming
  • 120V, 277V, 347V applications

7 Conductor

  • Max. 10 amp in a 1 circuit application
  • Max. 5 amps per circuit in a multi-circuit application
  • Max. 600V
  • Good for 3 circuit feeds or 2 circuit feeds with a battery pack hot lead
  • 120V, 277V, 347V applications